SPECIFICATION

Product Overview

Polymer rooms that still run on manual preparation show the same pattern: lumps forming in the tank, a solution strength that drifts between shifts, and one operator tied to the powder scoop instead of watching the plant. The cost rarely appears as a line item — it hides in overdosed chemical, blocked dosing lines and a flocculation step nobody quite trusts.

An automatic PAM dosing system takes that routine off the shift. Dry powder is metered out of the hopper by a screw feeder, wetted in a pre-mixing section and left to mature, then drawn off as a ready solution — one packaged unit standing in for a mixing tank, a feeder and a control panel.

Units like these sit in municipal sewage works, industrial wastewater treatment plants and chemical processing sites, wherever polymer is dosed as a flocculant ahead of sedimentation, thickening or dewatering. They are sized to a duty point rather than picked off a shelf.

Built as custom water treatment equipment rather than a catalogue item, the range spans five preparation capacities, so a small works and a large industrial plant run the same logic: powder in, matured solution out, with the operating state visible at the cabinet and at the plant supervisory system. That spread matters at specification stage, because one platform can serve a single polymer room or a plant with a continuous draw.

What separates an automatic chemical dosing system from a feeder bolted to a tank is the closed loop — feeder speed, water supply and dosing output are supervised together. Solution strength then holds where it was set instead of drifting with the operator's attention.

Powder-to-Solution Preparation

  1. Dry powder rests in the hopper, where a silo vibrator keeps it moving and a heating and moisture-proof device holds the feed conditions steady, so the screw below receives an even supply instead of a caked bridge.
  2. The screw feeder runs under closed-loop control of its speed.
  3. That is what holds the feed volume to the set value when hopper level and powder bulk density change through the day.
  4. A water-material pre-mixing device wets the powder as it joins the water stream, accelerating hydration and preventing the dry pockets that later turn into agglomerates and blocked lines.
  5. The three-channel overflow body provides the residence time: preparation, maturation and overflow are separated into stages, so solution leaves for the dosing point only after it has fully matured under the specified preparation amount and continuous dosing conditions.
  6. Dry powder dosage automatically follows changes in influent flow, which is how a constant solution concentration is held when the plant load moves between morning and night.
  7. From there the matured solution is drawn off continuously.
  8. In an automatic chemical dosing system this is the stage that replaces the manual batch cycle, the stirring paddle and the operator standing over it.

Control & Automation Systems

A PLC runs the sequence from preparation through maturation to dosing. In an automatic chemical dosing system that logic, rather than the pump alone, is what keeps the delivered concentration steady shift after shift.

Fault alarm and automatic shutdown are built into that logic. When a condition falls outside range the system alarms and stops instead of continuing to feed powder or run the water side blind, which keeps both the machine and the process out of trouble.

An industrial Ethernet interface carries parameters up to the plant supervisory level, so the dosing duty can be watched from the control room rather than from the polymer room. Parameter upload also means the setpoints live in the plant record instead of on a whiteboard.

Two-way communication keeps the unit and the plant monitoring system in step, while a precise algorithm tracks the running state of each component — feeder, water supply, mixing and dosing — so an operator can see where the process stands without walking the room. Where a component starts to drift, that view usually shows it before the solution does.

On the cabinet, a touchscreen, indicator lights and an emergency stop keep local control simple for whoever is on shift. A programmable dosing system should read as clearly at the panel as it does on a remote screen.

Infographic showing intelligent control and customizable dosing optionsSpecification table for HCJY-PAM and HCJY-PP chemical dosing systemsApplication scenarios: waterworks, municipal sewage, hospital wastewater, reclaimed water reuse
Stainless steel automatic chemical preparation machine with hopper and control cabinet

Specifications

Model rangeHCJY-PAM-1000 to HCJY-PAM-5000 — the values below are given in model order
Preparation capacity1,000 / 2,000 / 3,000 / 4,000 / 5,000 L/h
Powder dosing rate1–3 / 2–6 / 3–9 / 4–12 / 5–15 kg/h at 1–3‰ solution strength
Dimensions (L×W×H)1800×1000×900 / 2050×1000×1050 / 2440×1220×1050 / 3150×1260×1260 / 3500×1400×1300 mm
Hopper capacityInlet Diameter&Min. Water Inflow
Inlet diameterDN25 / DN25 / DN32 / DN32 / DN40
Minimum water inflow1,500 / 3,000 / 4,500 / 6,000 / 7,500 L/h
Main engine power2.5 kW domestic / 1.4 kW imported on the 1,000 and 2,000; 3.0 kW / 1.4 kW on the 3,000; 3.0 kW / 2.5 kW on the 4,000 and 5,000
Main engine weight350/1,800 kg (1000); 410/2,350 kg (2000); 700/3,500 kg (3000); 800/5,300 kg (4000); 900/6,600 kg (5000) — no load / full load
Mixer optionDomestic or imported
Body materialStainless steel, PVC or carbon steel anti-corrosion
ControlPLC with fault alarm, automatic shutdown and industrial Ethernet interface

Capacity Sizing

  1. Start with the powder.
  2. PAM dosing system manufacturers size from the dry feed rate first, because the feeder sets the ceiling on everything downstream — note the flow you treat and the polymer dose the process needs before comparing capacities.
  3. Match that kg/h figure against the powder dosing row of the specification table and leave headroom; a unit running at the top of its feed band has nothing left for a load swing.
  4. Check the preparation capacity against the solution volume your wastewater treatment dosing point actually draws.
  5. Preparation and maturation run continuously, so both have to be covered at the same time rather than one after the other.
  6. Confirm the water side where the unit will stand: the inlet diameter and minimum water inflow for the model you are considering both have to be available at that point, not piped across the room.
  7. Look at the floor.
  8. Full-load weight is several times the dry weight, so a slab, mezzanine or container base needs checking before the unit is placed, not after it is filled.
  9. Where the plant has batch or seasonal peaks, size on the highest powder rate the process can call for; the closed-loop feeder turns down at low load, but it cannot feed beyond its rated band.

Installation & Commissioning

  • The unit arrives as a skid-mounted assembly — tank body, hopper, screw feeder, control cabinet and the piping manifold with its valves — so site work is connection and commissioning rather than assembly.
  • Because this is custom water treatment equipment, the drawings issued for your project govern the connection positions; set the plinth and the pipe stubs from those drawings rather than from a generic layout.
  • The integrated body keeps the installation compact: preparation, maturation and overflow share one structure, so the unit takes a single footprint in the polymer room instead of a row of separate tanks.
  • Connect power and the control link before any powder goes in, and test the alarm and shutdown path at the same time — a fault that only shows up mid-batch costs a day of production.
  • Commission in sequence: wet the system and check the pre-mixing water flow, set the preparation amount, let the first batch mature for the full period, then bring the dosing output up against the influent flow signal.
  • First-week checks are mostly about powder and water rather than control logic: hopper level and powder condition, vibrator and heater operation, feeder speed against the setpoint, and a look at the alarm log.
  • Maintenance load stays low because there is very little to take apart — the overflow body has no moving parts, so routine work is inspection of the feeder, vibrator and heater rather than rebuilds.

Ordering & Delivery

  • Have the duty figures ready when you order: treated flow, target polymer dose, the water and power you can supply, and the footprint you can give the unit.
  • As PAM dosing system manufacturers we confirm capacity, footprint and control interface against drawings before fabrication starts.
  • Confirm the site utilities before release: supply voltage, frequency and phase for the cabinet, and whether the mixer is to be the domestic or the imported unit.
  • Both do the same duty, and the choice is fixed at order.
  • Check the drawing set against the plant room — connection positions, inlet size, drain and overflow, and the control interface your network expects.
  • Changes after fabrication cost time on both sides.
  • Agree packing, shipping terms and the delivery schedule for your destination with your sales contact, and confirm lifting points and site access at the same time; custom water treatment equipment of this size travels as a skid.
  • Lead time is set per project once the configuration and drawings are approved — ask your sales contact for the current schedule for your unit.
  • Payment terms, manual language and any inspection or witness points are agreed with your sales contact before shipment, so the paperwork is settled before the unit leaves.
  • Specification sheet (download) | Range sheet covering preparation capacity, powder dosing rate, dimensions, hopper capacity, inlet diameter and minimum water inflow for every model Dimensional drawing | Overall footprint and connection positions for civil works and pipe routing Process flow diagram | Water, powder and solution paths through the unit, including the maturation and overflow stages Electrical and control schedule | Cabinet supply requirements, signal list and the industrial Ethernet connection point Operation and maintenance manual | Start-up sequence, maturation and dosing set-up, alarm handling and routine inspection points Recommended spares | Feeder, vibrator and heater items worth holding for routine upkeep

Technical Support & Model Matching

Send us your duty point, available utilities and site constraints, and our engineers will select the appropriate dosing system for the application and confirm the configuration with you before anything is built — including custom designs where the project calls for it. That support continues after delivery: our technical team assists with installation and commissioning guidance, operator handover, fault finding and spare-part replacement, and we provide the drawings and specifications your project team needs. Share your process details and we will come back with a recommended model and a clear technical proposal.

FAQ

How long does the solution in a PAM dosing system need to mature before it can be dosed?

Under the specified preparation amount and continuous dosing conditions, maturation takes more than an hour, and the overflow body is sized to give the solution that time. Shortening it is a false economy: unmatured solution carries lumps and unopened powder through to the dosing point, where it does little for flocculation and a lot for blocked lines.

Does the dosing rate follow changes in the influent flow?

Yes. Dry powder dosage automatically follows the influent flow, so the solution concentration stays constant as the load on a wastewater treatment plant moves through the day. The closed-loop control on the screw feeder makes that adjustment without an operator stepping in.

What should the operator do when the alarm goes off?

Treat it as a stop signal rather than a warning to watch. The PLC has already shut the system down so powder is not fed into a unit that cannot prepare or dose it. Read the alarm screen for the section flagged — feed, water, mixing or dosing — clear the cause, then restart the sequence from preparation.

Can the unit be supervised from our plant control room?

The control system provides an industrial Ethernet communication interface, so parameters can be uploaded and the duty monitored at a higher level. A dosing system configured in this way should read clearly in both places: the cabinet touchscreen for the operator on shift, and the supervisory screen for the control room.

Which model fits a small works and which fits a large plant?

The range runs from 1,000 to 5,000 L/h preparation capacity with powder dosing from 1–3 kg/h up to 5–15 kg/h. A small works with an intermittent draw sits at the lower end; a large industrial plant with continuous dosing moves up the range. The governing figure is the dry powder rate you need at peak, not vessel volume on its own.